KONOCare

Preventative Maintenance

Kono Kogs technician servicing a regenerative thermal oxidizer

What is KONOCare?

Kono Kogs will create a custom KONOCare RTO preventive maintenance program for your plant and equipment, regardless of oxidizer OEM. Over our 25+ year history we’ve worked with virtually all makes and models, and our core team has 150+ years of combined application and technical experience.

Maintenance Programs Optimized for YOUR Specific Needs

KONOCare preventive maintenance (PM) plans have been developed with the help of our Fortune 500 customers. The goal: maximum oxidizer uptime. Starting with a goal of zero non-scheduled downtime, we set out to define the most practical path to that goal.

The number one cause of oxidizer lost time is part failure. Identifying at-risk parts or deteriorating oxidizer health well before they impact performance or up-time is what drives our KONOCare PM plans. These plans also point to the importance of collaboration between Kono Kogs and our customers in this effort. Equipping, training and communicating with your in-house maintenance team will lead to the success we each desire.

We offer 4 plan levels to meet your uptime goals

KONOCare Plan Options

Silver is the most popular plan among our clients. However, it’s not the answer for every facility, or every emission airstream. Difficult applications or stringent emission regulations will require more diligent and frequent PM to keep your oxidizer running efficiently and your facility in compliance.

Select a KONOCare plan option below to learn more about what it includes:

KONOCare Diamond

Our top-of-the-line offering.

Well received by our largest customers.

KONOcare Diamond
Preventive Maintenance Visits
Quarterly
Remote Monitoring Hours
90 hours
Additional Remote Monitoring
Optional1
On-site customer personnel training (KKI technician)
2 days
On-site customer personnel training (KKI engineer)
2 days
Monthly Maintenance reminder e-mails
Yes
Parameter Monitoring / Recordkeeping
Monthly
Additional Reports: Trends / Concerns
Monthly
Vibration Analysis
Yes
Spare Parts2
Extensive
1 Optional service
2
Customized for each system to meet your needs
About KONOCare Diamond

The Diamond level PM plan is our top-of-the-line offering and has been well received by our largest customers and plants with no ability to produce goods without a functioning oxidizer.

KONOCare Diamond includes:

#1: Extensive spare parts package covering:

  • Critical level
  • Secondary level
  • “What if” level

#2: Remote monitoring hardware/setup (if not already installed)

#3: Extensive onsite training for plant leadership & maintenance personnel

  • In-class training
  • Principles of oxidizer operation
  • Control loop review
  • Importance of record keeping
  • On-machine training
  • Component identification
  • Terminology
  • Identify data point locations for record keeping

#4: Highest level of on-demand 24/7 remote monitoring of oxidizer; with option for additional billed support

#5: Monthly maintenance reminders by e-mail

#6: Extensive training of plant & maintenance personnel during initial PM visit

  • Review operation & maintenance requirements with plant personnel
  • Review recordkeeping requirements: visual, pressures, temperatures, amperages
  • Discuss KONOCare maintenance reports and what to expect in the reports

#7: Quarterly onsite PM inspections

  • Review the following with plant personnel:
  • Past KONOCare maintenance reports and any open items
  • Service calls since previous PM visit
  • Alarms since previous PM visit
  • Parameter sheets (stressing the importance of recordkeeping)
  • Trends seen in parameter records and their meaning

#8: Monthly remote monitoring of oxidizer operation

  • Running record of oxidizer parameters: pressure, temperature, amperage
  • Report on observable trends in parameters
  • Identify at-risk parts and oxidizer health risks

Why our largest clients love KONOCare Diamond: The combination of trained eyes on the equipment both quarterly and remotely, plus trained and engaged onsite maintenance personnel, will ensure the oxidizer system can be relied on in both the short and long term.

Regenerative thermal oxidizer preventive maintenance inspection checklist
Download a sample PDF report here.

What should I expect for the onsite preventative maintenance visit?

All KONOCare plans include at least one annual onsite preventive maintenance visit.

Typically, preventive maintenance service takes place over two days. The air pollution control system will need to be shut down (and cooled) before our technician begins, and remain shut down for the first day of preventive maintenance. This involves a complete internal and external mechanical inspection, including consumable component replacement. On the 2nd day the system will be on and off as we perform operational testing.

Day 1 includes mechanical inspection of:

  • Combustion chamber
  • Compressed air piping
  • Gas train
  • Dampers
  • Poppet/Rotary valves
  • Ceramic media
  • Catalyst
  • Insulation
  • Fans
  • Ductwork
  • Exhaust stack
  • Burner(s)
  • Expansion joint(s)
  • Control panels
  • Plenums
  • Flame safeguard unit
  • Cold face
  • External hot spots

Kono Kogs maintains a large inventory of replacement oxidizer parts. We also have our own fab shop and can produce custom components if necessary. Even more importantly, our team has the skills and knowledge to keep your process running reliably at peak efficiency.

Day 2:

The second day involves performance evaluation, including a complete review of system operation in on-line and off-line modes, electrical inspection and component testing. On day two the system will be started up and shut down to conduct process control and operational analysis.

Day 2 evaluation and testing includes but isn’t limited to:

  • System startup cycle
  • Online conditions
  • Safety shutdown
  • Alarms
  • Valve cycling
  • Pressure control loops
  • Temperature profile
  • Pressure/temperature controls
  • Relays
  • Test all safety switches/logic
  • Burner tuning
  • Burner controls
  • Airflow switches
  • Internal hot spot inspection/repair
  • Thermocouples (replace TCs in combustion chamber)
  • Actuators
  • Motors
  • Variable frequency drive (VFD)
  • HMI & communication devices
  • Data recorder

After each preventive maintenance visit you’ll get a detailed report including:

  • Full checklist of system components & operations reviewed on site
  • Work completed by technician
  • Results of testing
  • Critical findings requiring action
  • Photo record of all areas, especially critical areas
  • Recommended monthly maintenance plan

To better understand the level of inspection and detail covered during a preventive maintenance visit by Kono Kogs, view or download our RTO inspection sample report PDF:

SAMPLE REPORT

KONOCare Platinum

Everything offered in Gold

+ plus
very high-end support, oversight and reporting

Preventive Maintenance Visits
Quarterly
Remote Monitoring Hours
60 hours
Additional Remote Monitoring
Optional 1
On-site customer personnel training (KKI technician)
1 day
On-site customer personnel training (KKI engineer)
1 day
Monthly Maintenance reminder e-mails
Yes
Parameter Monitoring / Recordkeeping
Quarterly
Additional Reports: Trends / Concerns
Quarterly
Vibration Analysis
Optional 1
Spare Parts2
Critical
1 Optional service
2
Customized for each system to meet your needs
About KONOCare PlatinumGold Levels

KONOCare Platinum and KONOCare Gold include services that fall between Diamond (above) and Silver (below). Each KONOCare plan is optimized to suit your needs.

Share your application with us for a custom recommendation and quote.

What should I expect for the onsite preventative maintenance visit?

All KONOCare plans include at least one annual onsite preventive maintenance visit.

Typically, preventive maintenance service takes place over two days. The air pollution control system will need to be shut down (and cooled) before our technician begins, and remain shut down for the first day of preventive maintenance. This involves a complete internal and external mechanical inspection, including consumable component replacement. On the 2nd day the system will be on and off as we perform operational testing.

Day 1 includes mechanical inspection of:

  • Combustion chamber
  • Compressed air piping
  • Gas train
  • Dampers
  • Poppet/Rotary valves
  • Ceramic media
  • Catalyst
  • Insulation
  • Fans
  • Ductwork
  • Exhaust stack
  • Burner(s)
  • Expansion joint(s)
  • Control panels
  • Plenums
  • Flame safeguard unit
  • Cold face
  • External hot spots

Kono Kogs maintains a large inventory of replacement oxidizer parts. We also have our own fab shop and can produce custom components if necessary. Even more importantly, our team has the skills and knowledge to keep your process running reliably at peak efficiency.

Day 2:

The second day involves performance evaluation, including a complete review of system operation in on-line and off-line modes, electrical inspection and component testing. On day two the system will be started up and shut down to conduct process control and operational analysis.

Day 2 evaluation and testing includes but isn’t limited to:

  • System startup cycle
  • Online conditions
  • Safety shutdown
  • Alarms
  • Valve cycling
  • Pressure control loops
  • Temperature profile
  • Pressure/temperature controls
  • Relays
  • Test all safety switches/logic
  • Burner tuning
  • Burner controls
  • Airflow switches
  • Internal hot spot inspection/repair
  • Thermocouples (replace TCs in combustion chamber)
  • Actuators
  • Motors
  • Variable frequency drive (VFD)
  • HMI & communication devices
  • Data recorder

After each preventive maintenance visit you’ll get a detailed report including:

  • Full checklist of system components & operations reviewed on site
  • Work completed by technician
  • Results of testing
  • Critical findings requiring action
  • Photo record of all areas, especially critical areas
  • Recommended monthly maintenance plan

To better understand the level of inspection and detail covered during a preventive maintenance visit by Kono Kogs, view or download our RTO inspection sample report PDF:

SAMPLE REPORT

KONOCare Gold

Everything in Silver

+ plus minimum remote support and reporting

Preventive Maintenance Visits
Semi annual
Remote Monitoring Hours
30 hours
Additional Remote Monitoring
Optional 1
On-site customer personnel training (KKI technician)
Half day
On-site customer personnel training (KKI engineer)
Optional 1
Monthly Maintenance reminder e-mails
Optional 1
Parameter Monitoring / Recordkeeping
Semi annual
Additional Reports: Trends / Concerns
Semi annual
Vibration Analysis
Optional 1
Spare Parts2
First level
1 Optional service
2
Customized for each system to meet your needs
About KONOCare PlatinumGold Levels

KONOCare Platinum and KONOCare Gold include services that fall between Diamond (above) and Silver (below). Each KONOCare plan is optimized to suit your needs.

Share your application with us for a custom recommendation and quote.

What should I expect for the onsite preventative maintenance visit?

All KONOCare plans include at least one annual onsite preventive maintenance visit.

Typically, preventive maintenance service takes place over two days. The air pollution control system will need to be shut down (and cooled) before our technician begins, and remain shut down for the first day of preventive maintenance. This involves a complete internal and external mechanical inspection, including consumable component replacement. On the 2nd day the system will be on and off as we perform operational testing.

Day 1 includes mechanical inspection of:

  • Combustion chamber
  • Compressed air piping
  • Gas train
  • Dampers
  • Poppet/Rotary valves
  • Ceramic media
  • Catalyst
  • Insulation
  • Fans
  • Ductwork
  • Exhaust stack
  • Burner(s)
  • Expansion joint(s)
  • Control panels
  • Plenums
  • Flame safeguard unit
  • Cold face
  • External hot spots

Kono Kogs maintains a large inventory of replacement oxidizer parts. We also have our own fab shop and can produce custom components if necessary. Even more importantly, our team has the skills and knowledge to keep your process running reliably at peak efficiency.

Day 2:

The second day involves performance evaluation, including a complete review of system operation in on-line and off-line modes, electrical inspection and component testing. On day two the system will be started up and shut down to conduct process control and operational analysis.

Day 2 evaluation and testing includes but isn’t limited to:

  • System startup cycle
  • Online conditions
  • Safety shutdown
  • Alarms
  • Valve cycling
  • Pressure control loops
  • Temperature profile
  • Pressure/temperature controls
  • Relays
  • Test all safety switches/logic
  • Burner tuning
  • Burner controls
  • Airflow switches
  • Internal hot spot inspection/repair
  • Thermocouples (replace TCs in combustion chamber)
  • Actuators
  • Motors
  • Variable frequency drive (VFD)
  • HMI & communication devices
  • Data recorder

After each preventive maintenance visit you’ll get a detailed report including:

  • Full checklist of system components & operations reviewed on site
  • Work completed by technician
  • Results of testing
  • Critical findings requiring action
  • Photo record of all areas, especially critical areas
  • Recommended monthly maintenance plan

To better understand the level of inspection and detail covered during a preventive maintenance visit by Kono Kogs, view or download our RTO inspection sample report PDF:

SAMPLE REPORT

KONOCare Silver

Minimum recommended level of preventive maintenance

Preventive Maintenance Visits
Annual
Remote Monitoring Hours
Optional 1
Additional Remote Monitoring
Optional 1
On-site customer personnel training (KKI technician)
Optional 1
On-site customer personnel training (KKI engineer)
Optional 1
Monthly Maintenance reminder e-mails
Optional 1
Parameter Monitoring / Recordkeeping
Optional 1
Additional Reports: Trends / Concerns
Optional 1
Vibration Analysis
Optional 1
Spare Parts2
Optional 1
1 Optional service
2
Customized for each system to meet your needs
KONOCare Silver details

All KONOCare plans include at least one annual onsite preventive maintenance visit.

Our KONOCare Silver package is our most popular package for RTO owners looking for baseline protection from unexpected downtime. KONOCare Silver includes an extensive annual RTO inspection. Details can be seen here.

What should I expect for the onsite preventative maintenance visit?

All KONOCare plans include at least one annual onsite preventive maintenance visit.

Typically, preventive maintenance service takes place over two days. The air pollution control system will need to be shut down (and cooled) before our technician begins, and remain shut down for the first day of preventive maintenance. This involves a complete internal and external mechanical inspection, including consumable component replacement. On the 2nd day the system will be on and off as we perform operational testing.

Day 1 includes mechanical inspection of:

  • Combustion chamber
  • Compressed air piping
  • Gas train
  • Dampers
  • Poppet/Rotary valves
  • Ceramic media
  • Catalyst
  • Insulation
  • Fans
  • Ductwork
  • Exhaust stack
  • Burner(s)
  • Expansion joint(s)
  • Control panels
  • Plenums
  • Flame safeguard unit
  • Cold face
  • External hot spots

Kono Kogs maintains a large inventory of replacement oxidizer parts. We also have our own fab shop and can produce custom components if necessary. Even more importantly, our team has the skills and knowledge to keep your process running reliably at peak efficiency.

Day 2:

The second day involves performance evaluation, including a complete review of system operation in on-line and off-line modes, electrical inspection and component testing. On day two the system will be started up and shut down to conduct process control and operational analysis.

Day 2 evaluation and testing includes but isn’t limited to:

  • System startup cycle
  • Online conditions
  • Safety shutdown
  • Alarms
  • Valve cycling
  • Pressure control loops
  • Temperature profile
  • Pressure/temperature controls
  • Relays
  • Test all safety switches/logic
  • Burner tuning
  • Burner controls
  • Airflow switches
  • Internal hot spot inspection/repair
  • Thermocouples (replace TCs in combustion chamber)
  • Actuators
  • Motors
  • Variable frequency drive (VFD)
  • HMI & communication devices
  • Data recorder

After each preventive maintenance visit you’ll get a detailed report including:

  • Full checklist of system components & operations reviewed on site
  • Work completed by technician
  • Results of testing
  • Critical findings requiring action
  • Photo record of all areas, especially critical areas
  • Recommended monthly maintenance plan

To better understand the level of inspection and detail covered during a preventive maintenance visit by Kono Kogs, view or download our RTO inspection sample report PDF:

SAMPLE REPORT

Customizing Your KONOCare Plan

In most cases we recommend an annual evaluation of all air pollution control equipment, though semi-annual or quarterly evaluations may be necessary depending on system complexity and the service requirements in your environmental operating permit.

RTO preventive maintenance visits can be flexible to accommodate your schedule. For example, a one-day preventive maintenance visit every six months instead of two consecutive days each year. Together we’ll design a program that meets your needs with minimal disruption to operations.

We can also bundle other oxidizer services with your preventive maintenance visit, including:

Remote Access & Troubleshooting

KKI also offers remote monitoring and troubleshooting services. These can be included as part of your customized KONOCare plan, or billed hourly outside of our KONOCare program.

Benefits of Oxidizer Preventive Maintenance

Preventive maintenance offers several benefits directly affecting your bottom line:

  • Minimize unplanned downtime & lost production
  • Minimize oxidizer repair costs
  • Extend the practical service life of your RTO
  • Optimize equipment performance for energy efficiency
  • Improve safety
  • Establish a record of DRE compliance

Many states require facilities with thermal oxidizers to keep records of their equipment maintenance program. Fines can be issued for noncompliance in recordkeeping, even if the system is operating properly. If a device fails to meet the control requirements defined in the permit, the monetary penalty can be significant, and also gets you “noticed” in a way that you don’t want – another good reason to create and maintain a regular DRE compliance record.

The experts at Kono Kogs give you peace of mind, keeping your oxidizer operating and compliant, energy costs in check, and interactions with the EPA to a minimum.

Request Service Form

Please fill the form below to receive a service quote. You can also call us 24/7/365 at 920-615-8804 or send us an email.

1
2
3
4

Contact details

Please fill out the required fields

1
2
3
4

Address of Service Request

1
2
3
4

Details of the request *

1
2
3
4

Submit your service request

Before submitting, please take a moment to review all the information you've provided in the previous steps for accuracy and completeness. Thank you!

Previous step
Next step

Thank you! Your submission has been received!

Thank you for submitting the details of the equipment you need service for. We will review the information and contact you within 24-48 hours to discuss the next steps in the service process. If you have additional photos or documentation to send, please email them to service@konokogs.com. Alternatively, you can call us 24//365 at 920-615-8804. Thank you!

We're sorry, but there seems to be an issue with submitting your form. Please try again, and ensure that all required fields are filled out correctly. If the problem persists, please contact our sales team for assistance at 920-615-8804 or service@konokogs.com.